Chiller INVERTER Variable Capacity - Series 410

Banneringlese chiller new

AIR CONDITIONER CHILLER INVERTER VARIABLE CAPACITY - 410 SERIES

 

Advanced Inverter Variable capacity technology coupled with R410A refrigerant provides the benefits of:

- low operation noise
- elimination of starting current peaks
- rapid cooling
- heating as well as maximum energy efficiency.

ADVANTAGES

- ENERGY SAVING (-45% ELECTRICAL CONSUMPTION)
- ONLY 2A PEAK CURRENT AT STARTING
- HIGHER AIR CONDITIONING RELIABILTY
- POSSIBILITY TO REDUCE THE POWER GENERATOR SIZE
- REFRIGERANT FLUID R410A
- COMPLY WITH EMC DIRECTIVE
View the data sheet of
Chiller Inverted BLDC - Serie 410

Download

607 NT

Art.607 NT

 
607 NT
Width
331mm
13 in
Height
436 mm
17.2 in
Depth
476 mm (+10mm pipe)
18.7 in ( + 3.9 in pipe)
Weight
48 kg
106 lbs
Voltage
150 - 260 VAC
Cycle - Phase
50 - 60 hz
1 Ph
Max cooling capacity
42.000 BTU/h
3.5 T
Max heating capacity
42.000 BTU/h
3.5 T
Max input power
2,2 kW
2.2 kW
Max Current
10,5 A
10.5 A
Max input power
(ECO function)
0,9 kW
0.9 kW
Max current
(ECO function)
4,5 A
4.5 A
Refrigerant R410A
0,93 kg
2.1 lbs
607NT.jpg
Working limits:

Seawater temperature in winter mode 
(winter) > 5°C 41°F
Seawater temperature in summer mode (summer) < 40°C / 104°F
Engine room temperature < 70°C / 158° F

608 NT

Art.608 NT

 
608 NT
Width
431mm
17 in
Height
436 mm
17.2 in
Depth
476 mm (+10mm pipe)
18.7 in ( + 3.9 in pipe)
Weight
64 kg
141 lbs
Voltage
150 - 260 VAC
Cycle - Phase
50 - 60 hz
1 Ph
Max cooling capacity
62.000 BTU/h
5.2 T
Max heating capacity
62.000 BTU/h
5.2 T
Max input power
3,5 kW
3.5 kW
Max Current
16 A
Max input power
(ECO function)
1,2 kW
1.2 kW
Max current
(ECO function)
6,1 A
6.1 A
Refrigerant R410A
1,1 kg
2.4 lbs
608NT
Working limits:

Seawater temperature in winter mode (winter) > 5°C 41°F
Seawater temperature in summer mode (summer) < 40°C / 104°F
Engine room temperature < 70°C / 158° F

TECHNICAL DATA

Inverter Brushless DC Technology.
This technology is used to control the speed of the compressor motor to allow continuously regulated temperature; by contrast traditional air conditioners regulate temperature by using a compressor that is periodically either working at maximum capacity or completely switched off. The inverter air conditioner is equipped with a variable frequency driven brushless DC compressor that incorporates an adjustable electrical inverter to control the speed of the motor and thus the compressor and cooling output. Eliminating stop-start cycles considerably increases the energy efficiency, extends the life of components and eliminates sharp fluctuations on water temperature and power supply. By using the Inverter Brushless DC Air conditioner it is possible to reduce on board the size of power generator.


Energy saving (-45% in average electrical energy consumption).
After the water temperature approaches the set temperature, Inverter Control adjusts to low capacity operation to maintain this temperature. Variable capacity operation together with brushless DC motor higher efficiency make inverter air conditioning more energy-saving than non-inverter models, which must repeatedly start or stop their compressors to maintain the water temperature. In term of Seasonal Efficiency Ratio, the average reduction in electrical energy consumption is 45%, compared to the equivalent traditional air conditioner

 

Smooth starting (No peak current at start)
Starting ramp is set at very low frequency (20 Hz) allowing very low starting torque and starting current, far below the nominal value. The max starting current is 2 A, while for the equivalent traditional air conditioner the max starting current is 60-70 A, even with soft starting devices.

 

Powerful
Inverter air conditioning operates at maximum capacity after start up phase. As a result, the set temperature is reached more quickly.

 

Comfortable
Inverter air conditioning finely adjust capacity according to changes in the air-conditioning load and the difference between the water temperature and set temperature is very small. These give much higher comfort levels than with non-inverter air conditioners. Thanks to brushless DC motors and sound shields the operation noise is very low.

 

Variable Capacity Operation (ECO function)
Inverter air conditioning is able to vary its operating capacity. Non-inverter air conditioners can only operate at a fixed capacity. ECO function is available on inverter air conditioning, to further reduce power supply whenever other electrical appliances are being used in the same time.

 

Relaiable
Brushless DC motor together with variable capacity operation allow a much longer compressor lifetime than non-inverter models, which must repeatedly start or stop their compressors during operation stressing motor coils.


Easy installation

Very small overall dimensions, no need of drain (thanks to thermal insulation) and possibility to install the display controller in different positions.


Comply with EMC Directive
The equipment complies with the Electromagnetic Compatibility (EMC) Directive 2004/108/EC.